{"product_id":"ultrasonic-flow-meter-for-liquids-pce-tds-200-sm","title":"Ultrasonic Flow Meter for Liquids PCE-TDS 200 SM","description":"\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-center\"\u003e\u003cstrong\u003eUltrasonic Flow Meter for Liquids with 32 GB data memory \/ measuring range ±32 m\/s \/ reproducibility ±0.5 % of measured value \/ different measuring probes \/ alarm limit values \/ 2.8 \" LC display \/ for all media \/ optionally with DAkkS or ISO calibration certificate\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-justify\"\u003e\n\u003cp\u003eThe ultrasonic flowmeter for Liquids has a measuring range of ±32 m\/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN \u0026lt;50 and a reproducibility of ±0.5 % f.s., the Ultrasonic Flow Meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the Ultrasonic Flow Meter. The installation aid graphically displays the signal quality of the Ultrasonic Flow Meter. In addition, it is graphically displayed whether the sensors of the Ultrasonic Flow Meter are positioned at the correct distance from each other. To carry out flow measurements with the Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The Ultrasonic Flow Meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob. \u003cbr\u003e\u003cbr\u003eDuring a measurement, it is possible to record the measured values via the data logger function of the Ultrasonic Flow Meter for Liquids. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the Ultrasonic Flow Meter. A memory point of the Ultrasonic Flow Meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the Ultrasonic Flow Meter. 10 million measuring points can be stored on the Ultrasonic Flow Meter for Liquids.\u003cbr\u003e\u003cbr\u003eWith the optional software, the recorded measured values can be read out from the Ultrasonic Flow Meter for Liquids. For analysis, the measured values from the Ultrasonic Flow Meter can be displayed in tabular and graphic form. For further processing of the measured values from the Ultrasonic Flow Meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the Ultrasonic Flow Meter can be set via the software. A live view of the measured values from the Ultrasonic Flow Meter is also possible with the software. \u003cbr\u003e\u003cbr\u003eIn order to determine the amount of heat with the Ultrasonic Flow Meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the Ultrasonic Flow Meter for Liquids are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the Ultrasonic Flow Meter can determine the amount of heat. If required, the Ultrasonic Flow Meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the Ultrasonic Flow Meter for Liquids is used, for example, in the inspection of heating systems.\u003cbr\u003e\u003cbr\u003eThe LC colour display of the Ultrasonic Flow Meter has a size of 2.8\" and is therefore easy to read. Optionally, the Ultrasonic Flow Meter can be equipped with an ISO or DAkkS calibration certificate. \u003cbr\u003e\u003cbr\u003ePCE-TDS 200 S SENSOR\u003cbr\u003eSmall sensor pair for pipe diameters DN 15 ... 100 \/ 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flowmeter can be connected to the pipe by means of detachable cable ties. \u003cbr\u003e\u003cbr\u003ePCE-TDS 200 M SENSOR\u003cbr\u003eMedium sensor pair for pipe diameters DN 50 ... 700 \/ 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the Ultrasonic Flow Meter, they can be attached to ferrous pipes. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring range ±32 m\/s\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB-C interface for data transfer\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional software for analysing the measured values\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReproducibility ±0.5 % of measured value\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat quantity measurement\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eData memory for 10 million measuring points\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eindividually adjustable alarm limits\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eoptionally with ISO or DAkkS calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable border=\"0\" bgcolor=\"#fff\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-32 ... +32 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDN ≥50 mm: ±1.5 % of Rd for velocities \u0026gt;0.3 m\/s \/ DN \u0026lt;50 mm: ±3.5 % of Rd for velocities \u0026gt;0.3 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eUltrasonic sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDesignation  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePCE-TDS 200 S SENSOR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePipe diameter  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDN 15 ... 100 mm \/ Ø 20 ... 108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimension  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e45 x 30 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFrequency  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating temperature  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-30 ... 160 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensor cable length  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eUltrasonic sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDesignation  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePCE-TDS 200 M SENSOR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePipe diameter  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDN 50 ... 700 mm \/ Ø 57 ... 720 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimension  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e70 x 40 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFrequency  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-30 ... 160 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensor cable length  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eGeneral technical data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring functions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eFlow velocity, Volume flow, Volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eUnits  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003emetric, imperial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eUnits additional information  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDimensions: mm, in\u003cbr\u003eFlow velocity: m\/s, ft\/s\u003cbr\u003eVolume flow: m³, l, gal, igl, mgl, cf, bal, ib, ob\u003cbr\u003eVolume: m³, l, gal, igl, mgl, cf, bal, ib, ob\u003cbr\u003eTime specification: seconds, minutes, hours, days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay size  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2,8 Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage medium  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eInternal memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage capacity  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage interval from  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage interval to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e12 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePipe material  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSteel, Cast iron, Stainless steel, Aluminium, Brass, Copper, PVC, Iron, Nickel, Titanium, Zinc, Acrylic, Polyethylene, Polypropylene, Nylon, User-defined (manual entry of the transversal sound velocity of the pipe material)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePipe material additional information  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eInner lining of the pipe:\u003cbr\u003e- No lining\u003cbr\u003e- Epoxy resin\u003cbr\u003e- Rubber\u003cbr\u003e- Mortar\u003cbr\u003e- Polystyrene\u003cbr\u003e- Polyethylene\u003cbr\u003e- Polytetrafluoroethylene\u003cbr\u003e- Polyurethane\u003cbr\u003e- Polypropylene\u003cbr\u003e- Customised (manual entry of the longitudinal sound velocity of the inner lining of the pipe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasured medium  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eWater, Seawater, Oil, Crude oil, Methanol, Ethanol, Diesel, Petrol, Petroleum, User-defined (manual entry of the sound velocity of the medium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating time  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAutomatic power-off from...to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 ... 15 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAutomatic power-off can be deactivated  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring method  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eZ, V, N, W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAlarm  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eoptical, Acoustic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAlarm modes  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eUndercut, overflow, within, beyond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eReproducibility  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±0.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMenu language  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eTurkish, English, Polish, Spanish, German, Chinese, Russian, Japanese, French, Danish, Italian, Dutch, Portuguese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class (device)  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eUSB 5 VDC, 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eConnector type  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDevice-europlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCapacity  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2500 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-20 ... 65 °C , 10 ... 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-20 ... 65 °C , 10 ... 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attribute\"\u003e\n\u003ctd valign=\"top\"\u003eDimensions ( L x W x H )  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e165 x 85 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e263,5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDelivery Scope\u003c\/h3\u003e\n\u003cp\u003e1 x Ultrasonic Flow Meter PCE-TDS 200 SM\u003cbr\u003e1 x Flow sensors PCE-TDS 200 S SENSOR (pair)\u003cbr\u003e1 x flow sensors PCE-TDS 200 M SENSOR (pair)\u003cbr\u003e2 x 5 m connection cable\u003cbr\u003e2 x detachable cable ties\u003cbr\u003e1 x power supply unit\u003cbr\u003e1 x USB-C cable\u003cbr\u003e1 x ultrasonic contact gel\u003cbr\u003e1 x PCE measuring tape\u003cbr\u003e1 x plastic case\u003cbr\u003e1 x instruction manual\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE Instruments","offers":[{"title":"Default Title","offer_id":45235579650102,"sku":"PCE-TDS 200 SM","price":3272.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/9482\/5014\/files\/pce-instruments-ultrasonic-flow-meter-for-liquids-pce-tds-200-sm-6317978_2921674.webp?v=1775226291","url":"https:\/\/farmsteadfocus.com\/products\/ultrasonic-flow-meter-for-liquids-pce-tds-200-sm","provider":"Farmstead Focus","version":"1.0","type":"link"}