{"product_id":"ph-conductivity-salt-oxygen-water-quality-data-logger-pce-phd-1-kit1","title":"pH \/ Conductivity \/ Salt \/ Oxygen Water Quality Data Logger PCE-PHD-1-KIT1","description":"\u003cdiv\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cstrong\u003epH, conductivity, salt, oxygen and temperature measuring device\u003c\/strong\u003e\u003cstrong\u003e \/ \u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003eSD card memory (1 ... 16 GB), data is stored as an Excel file \/\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003elarge, easy-to-read display \/ RS-232 interface and \u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003eoptional software for direct transfer to the PC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: justify;\"\u003e\n\u003cp\u003eThe data logger PCE-PHD-1-KIT1 is a true all-rounder for checking water quality. The portable data logger is used to control the water parameters pH, redox, conductivity, salinity, oxygen and is also very suitable for temperature measurement. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA 2-point calibration and an automatic temperature compensation guarantees high accuracy even with highly fluctuating measuring temperatures. The data logging meter is supplied with pH and conductivity probe. Different probes are available as accessories. All values can be stored directly on the SD card (1 ... 16 GB) as an Excel file or transferred via the RS-232 interface directly from the device to a PC. For this we optionally offer software and the suitable RS-232 interface cable as an accessory.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eoptimal price\/performance ratio\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ereal-time datalogger\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSD memory card (1 ... 16 GB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ethe stored data is saved directly as an Excel file on the SD card\u003cbr\u003e   (no software needed for evaluation)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRS-232 interface for online data transmission\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003emeasures pH, redox (optional), conductivity, salinity, oxygen, and temperature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ehigh precision\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003elow-battery display\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003elarge LCD display\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eadjustable measuring rate\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eeasy to use\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003erobust housing\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eincl. pH and conductivity electrode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eautomatic calibration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003emanual or autom. temperature compensation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBNC connector\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003esuitable for laboratory and on-site measurement\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eREDOX Elektrode (optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" valign=\"top\"\u003e\u003cstrong\u003epH Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"212\" valign=\"top\"\u003e\n\u003cp\u003eautomatic 10 ... 40 °C \/ 50 ... 104 °F\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 0.02 pH +2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCalibration\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2-point calibration (pH4, pH7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAutomatic with additional temperature sensor (0 ... 60 ºC \/ 32 ... 140 ºF) or manual (0 ... 100 ºC \/ 32 ... 212 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cstrong\u003eRedox \u003c\/strong\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1999 ... 0 ... 1999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 0.5 % + 2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cstrong\u003eConductivity \u003c\/strong\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 200 μS\/cm\u003cbr\u003e0.2 ... 2.0 mS\/cm\u003cbr\u003e2 ... 20.0 mS\/cm\u003cbr\u003e20 ... 200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 μS\/cm\u003cbr\u003e0.001 mS\/cm\u003cbr\u003e0.01 mS\/cm\u003cbr\u003e0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 2 % of the measurement range + 1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCalibration\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eat 1413 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAutomatic (0 ... 60 ºC \/ 32 ... 140 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eTotal dissolved solids (TDS) Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 132 ppm\u003cbr\u003e132 ... 1320 ppm\u003cbr\u003e1320 ... 13200 ppm\u003cbr\u003e13200 ... 132000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 ppm\u003cbr\u003e1 ppm\u003cbr\u003e10 ppm\u003cbr\u003e100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 2 % of the measurement range + 1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAutomatic (0 ... 60 ºC \/ 32 ... 140 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cstrong\u003eSalt Content\u003c\/strong\u003e\u003cstrong\u003e Measurement\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 20 mg\/l (in water)\u003cbr\u003e0 ... 100 % (in air)\u003cbr\u003e0 ... 50 °C \/ 32 ... 122 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 mg\/l\u003cbr\u003e0.1 %\u003cbr\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 0.4 mg\/l\u003cbr\u003e± 0.7 %\u003cbr\u003e± 0.8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCalibration\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIn the air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature compensation\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAutomatic (0 ... 50 ºC \/ 32 ... 122 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eElectrode usable in the pH range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003epH 4 ... pH 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eTemperature Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 60 °C\/ 32 ... 140 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 0.8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement rate\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003eadjustable from 1 second to 8 hours 59 minutes 59 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLC-Display 52 x 38 mm \/ 2 x 1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMemory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003eflexible via SD card memory 1 ... 16 GB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSoftware\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan id=\"result_box\" lang=\"en\"\u003eavailable as accessory (optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6 x 1.5 V AA batteries \/ 9 V-power adapter (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... +50 °C \/ \u0026lt; 85 % r.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e177 x 68 x 45 mm \/ 7.0 in x 2.7 in x 1.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e490 g \/ 1.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDelivery Scope\u003c\/h3\u003e\n\u003cp\u003e1 x pH-Meter PCE-PHD-1-KIT1\u003cbr\u003e1 x oxygen probe OXPB-11\u003cbr\u003e1 x pH electrode PE-03\u003cbr\u003e1 x conductivity electrode CDPB-03\u003cbr\u003e1 x temperature sensor TP-07\u003cbr\u003e1 x SD memory card 2 GB\u003cbr\u003e1 x storage solution PCE-SSO-250 (250ml)\u003cbr\u003e1 x calibration solution PCE-PH4-50 (50ml)\u003cbr\u003e1 x calibration solution PCE-PH7-50 (50ml)\u003cbr\u003e1 x electrolyte solution OXEL-03 for oxygen probe (50ml)\u003cbr\u003e1 x conductance solution PCE-CDS-1413-250 (250ml)\u003cbr\u003e6 x batteries\u003cbr\u003e1 x user manual\u003cbr\u003e1 x carrying case (inner foam prepunched)\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PCE Instruments","offers":[{"title":"Default Title","offer_id":45073955586102,"sku":"PCE-PHD-1-KIT1","price":805.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/9482\/5014\/files\/pce-instruments-ph-conductivity-salt-oxygen-water-quality-data-logger-pce-phd-1-kit1-5858047_1140271.webp?v=1774029494","url":"https:\/\/farmsteadfocus.com\/products\/ph-conductivity-salt-oxygen-water-quality-data-logger-pce-phd-1-kit1","provider":"Farmstead Focus","version":"1.0","type":"link"}