{"product_id":"air-humidity-meter-pce-thd-50","title":"Air Humidity Meter PCE-THD 50","description":"\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eAir H\u003c\/strong\u003e\u003cstrong\u003eumidity Meter with connection for thermocouple type K \/ Measuring range -20 ... 60 °C \/\u003cbr\u003eRechargeable battery \/ Micro USB data interface \/ PC software \/\u003cbr\u003eData memory for 32,000 measuring points \/ Optionally with ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv align=\"justify\"\u003eThe air humidity meter is the ideal measuring device to check the climatic conditions in, for example, warehouses, production halls or greenhouses. The air humidity meter can measure the ambient temperature and humidity. Temperatures between -20 ... 60 °C (-4 ... 140 °F) can be measured reliably and quickly by the air humidity meter. In addition, the dew point and wet bulb temperature is calculated and displayed by the air humidity meter. In addition, any type K thermocouple can be connected to the air humidity meter in a temperature range of -100 ... 1372 °C (-148 ... 2501 °F). As soon as the connected thermocouple has been recognized, the temperature display automatically switches from the air humidity meter to the thermocouple.\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\n\u003cbr\u003eMeasured values can be recorded with the data logger function of the air humidity meter. The large memory of 32,000 measuring points in the air humidity meter allows recording of measured values over a long period of time. After data logging, all logged measuring points can be read out and analyzed via the micro-USB interface of the air humidity meter and the free software. The data logged by the air humidity meter can be exported in CSV file format for further processing.\u003cbr\u003e\u003cbr\u003eA 3.7 V Li-ion battery is installed in the air humidity meter to enable mobile use. This battery can be recharged via the micro-USB interface on the air humidity meter.\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli align=\"justify\"\u003eMeasuring range -20 ... 60 °C \/ -4 ... 140 °F\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli align=\"justify\"\u003eTemperature, humidity, dew point\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli align=\"justify\"\u003eBacklit LC display\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli align=\"justify\"\u003eMicro USB interface\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli align=\"justify\"\u003eRechargeable battery\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli align=\"justify\"\u003eData memory for 32,000 readings\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli align=\"justify\"\u003eWet bulb temperature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli align=\"justify\"\u003eOptionally with ISO calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAir temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-20 … 60 °C（-4 … 140 °F）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 °C\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±0.5 °C @ 0 … 45 °C，±1.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e in remaining range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±1.0 °F @ 32 … 113 °F，±2.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e in remaining range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring rate\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 … 100 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±2.2 % RH (10 … 90 % RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e@ 23 °C (73.4 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±3.2 % RH (\u0026lt;10，\u0026gt;90 % RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e @23 °C (73.4 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResponse time\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;10 s (90 % RH, 25 °C (77 °F), with no wind)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eThermoelement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensor type\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThermoelement Type K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-100 … 1372 °C（-148 … 2501 °F）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 °C\/°F, 0.1 °C\/°F, 1 °C\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1 % ±1 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCalculated values\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eWet bulb temperature  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-20 … 60 °C （-4 … 140 °F）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDew point temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-50 … 60 °C （-58 … 140 °F）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFurther specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInternal memory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e99 measuring points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e(redundant, only readable on the measuring device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e32,000 measuring points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e(only readable on the PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3.7 V Li-ion battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 … 40 °C (32 … 104 °F) \u0026lt;80 % RH,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003enon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 … 60 °C (14 … 140 °F) \u0026lt;80 % RH,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003enon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e162 mm x 88 mm x 32 mm \/ 6.3 x 3.4 x 1.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e248 g \/ 8.74 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDelivery Scope\u003c\/h3\u003e\n\u003cp\u003e1 x Air Humidity Meter PCE-THD 50\u003cbr\u003e1 x Type K thermocouple\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x PC software\u003cbr\u003e1 x Instruction manual \u003c\/p\u003e","brand":"PCE Instruments","offers":[{"title":"Default Title","offer_id":45073570037814,"sku":"PCE-THD 50","price":244.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/9482\/5014\/files\/pce-instruments-air-humidity-meter-pce-thd-50-5989281_1866350.webp?v=1774025552","url":"https:\/\/farmsteadfocus.com\/products\/air-humidity-meter-pce-thd-50","provider":"Farmstead Focus","version":"1.0","type":"link"}